Fire Hoods

  • View:
  • Grid
  • List

AU-FH150Intumescent Firehood suitable for use with downlight cut outs of up...

UK Patent GB2424693. International PCT / GB03/003229. Fully breathable fire hood for low/mains downlights allows heat. from the lamp to be effectively dissipated preventing the terminal. block and fitting from overheating. An intumescent material envelope expands to fill the hood and seal the downlight cut-out in the ceiling in the event of a fire in the room below. Suitable for 30 and 60 minute fire rated ceilings. Unique self supporting and adjustable fixing method allows for installation in ceilings up to 35mm thick. Failure to perform insurance - £10M cover (subject to correct installation). Tested to BS476 Part 21. In addition, Aurora firehoods are tested to BS EN 1365-2: 2014 (fire resistance). BS EN ISO 10140-2: 2010 & BS EN ISO 10140-3: 2010 + A1: 2015 (acoustics), confirming that they maintain the ability for an internal or seperating floor to provide sound insulation

AU-FH150/105/CFirehood suitable for use with downlight cut outs of up to 80mm dia...

Fire retardent material fire hood prevents the spread of fire in the event of a fire in the room below.Suitable for 30 and 60 minute fire rated ceilings.Unique self supporting and adjustable fixing method allows for installation in ceilings up to 35mm thick.Failure to perform insurance - £10M cover (subject to correct installation).Tested to BS476 Part 21

AU-FH150/105Intumescent Firehood suitable for use with downlight cut outs of up...

UK Patent GB2424693. International PCT / GB03/003229. Fully breathable fire hood for low/mains downlights allows heat. from the lamp to be effectively dissipated preventing the terminal. block and fitting from overheating. An intumescent material envelope expands to fill the hood and seal the downlight cut-out in the ceiling in the event of a fire in the room below. Suitable for 30 and 60 minute fire rated ceilings. Unique self supporting and adjustable fixing method allows for installation in ceilings up to 35mm thick. Failure to perform insurance - £10M cover (subject to correct installation). Tested to BS476 Part 21. In addition, Aurora firehoods are tested to BS EN ISO 10140-2: 2010. BS EN ISO 10140-2: 2010 & BS EN ISO 10140-3: 2010 + A1: 2015 (acoustics), that they maintain the ability for an internal or seperating floor to provide sound insulation

AU-FH150/CFirehood suitable for use with downlight cut outs of up to 80mm dia...

Fire retardent material fire hood prevents the spread of fire in the event of a fire in the room below.Suitable for 30 and 60 minute fire rated ceilings.Unique self supporting and adjustable fixing method allows for installation in ceilings up to 35mm thick.Failure to perform insurance - £10M cover (subject to correct installation).Tested to BS476 Part 21

AU-FH200Intumescent Firehood suitable for use with downlight cut outs of up...

UK Patent GB2424693.International PCT / GB03/003229.Fully breathable fire hood for low/mains downlights allows heat.from the lamp to be effectively dissipated preventing the terminal.block and fitting from overheating.An intumescent material envelope expands to fill the hood and seal the downlight cut-out in the ceiling in the event of a fire in the room below.Suitable for 30 and 60 minute fire rated ceilings.Unique self supporting and adjustable fixing method allows for installation in ceilings up to 35mm thick.Failure to perform insurance - £10M cover (subject to correct installation).Tested to BS476 Part 21.In addition, Aurora firehoods are tested to BS EN ISO 140-3:1995.& BS EN ISO 140-6:1998 (Acoustics), confirming that they maintain the ability for an internal or seperating floor to provide sound insulation

AU-FH250Intumescent Firehood suitable for use with downlight cut outs of up...

UK Patent GB2424693.International PCT / GB03/003229.Fully breathable fire hood for low/mains downlights allows heat.from the lamp to be effectively dissipated preventing the terminal.block and fitting from overheating.An intumescent material envelope expands to fill the hood and seal the downlight cut-out in the ceiling in the event of a fire in the room below.Suitable for 30 and 60 minute fire rated ceilings.Unique self supporting and adjustable fixing method allows for installation in ceilings up to 35mm thick.Failure to perform insurance - £10M cover (subject to correct installation).Tested to BS476 Part 21.In addition, Aurora firehoods are tested to BS EN ISO 140-3:1995.& BS EN ISO 140-6:1998 (Acoustics), confirming that they maintain the ability for an internal or seperating floor to provide sound insulation

AU-FH300Intumescent Firehood suitable for use with downlight cut outs of up...

UK Patent GB2424693.International PCT / GB03/003229.Fully breathable fire hood for low/mains downlights allows heat.from the lamp to be effectively dissipated preventing the terminal.block and fitting from overheating.An intumescent material envelope expands to fill the hood and seal the downlight cut-out in the ceiling in the event of a fire in the room below.Suitable for 30 and 60 minute fire rated ceilings.Unique self supporting and adjustable fixing method allows for installation in ceilings up to 35mm thick.Failure to perform insurance - £10M cover (subject to correct installation).Tested to BS476 Part 21.In addition, Aurora firehoods are tested to BS EN ISO 140-3:1995.& BS EN ISO 140-6:1998 (Acoustics), confirming that they maintain the ability for an internal or seperating floor to provide sound insulation

Upcoming Events

05
Mar

EuroShop 2017

Aurora will be exhibiting its new Smart retail display lighting at EuroS...

Registered South Africa Address: Aurora Lighting (Pty) Ltd | Building 6, Ground Floor | Pinewood Office Park | 33 Riley Road, Woodmead | Gauteng, South Africa

TEL: +27 (0) 11 234 4878 | FAX: +27 (0) 11 234 3460

1999 - 2016 auroralighting.com

 

 

France

Select Location & Language

Aurora Lighting is a global organization serving markets around the world. Please select your region, or click below to visit our Global site to view our 2,500 products: